One easy-to-use tool for testing solar panels and PV systems.
The Fluke IRR1-SOL Irradance Meter has been designed from the ground up to simplify the installation, commissioning and troubleshooting of photovoltaic arrays and solar panels. Whether surveying, installing, executing maintenance, or checking the performance of solar panels or photovoltaic systems there are four critical measurements that technicians require, and that the Fluke IRR1-SOL Irradiance Meter delivers:
- Solar irradance: Make instantaneous measurements to determine the watt per square meter solar irradiation, required by the IEC 62446-1 standard
- Ambient and PV module temperature: Measure temperature by either placing the meter directly on the panel or by connecting the external probe
- Array orientation: Find cardinal direction with the built-in compass
- Tilt angles: Verify inclination of a roof or panel with the tilt function
Built to go where you go
With a rugged, compact design, a protective carrying case, and an easy-to-read, high contrast LCD screen to read measurements in direct sunlight, the IRR1-SOL can go where you go. The simple user interface, instantaneous solar irradiation measurements, and built-in temperature for testing, documenting, and maintaining photovoltaic systems.
Key Features | IRR1-SOL |
Irradiance | |
Measuring Range | 50 to 1400 W/m² |
Resolution | 1 W/m² |
Measuring Accuracy | ± (5 % + 5 Digit) |
Temperature Measurement | |
Measuring range (°C) | -30 °C to 100 °C (-22 °F to 212 °F) |
Resolution | 0.1 °C (0.2 °F) / 1 °F @>100 °F |
Measuring Accuracy | ±1 °C (±2 °F) @ -10 °C to 75 °C (14 °F to 167 °F), ±2 °C (±4 °F) @ -30 °C to -10 °C (-22 °F to 14 °F) and 75 °C to 100 °C (167 °F to 212 °F) |
Note: Temperature measurement response time: ~30 sec. | |
Inclination Angle | |
Measuring Range | -90° to +90° |
Resolution | 0.1° |
Measuring Accuracy | ± 1.5°@ -50° to +50° ±2.5° @ -85° to -50° and +50° to +85° ±3.5° @ -90° to -85° and +85° to +90° |
Compass | |
Measuring Range | 0° to 360° |
Resolution | 1° |
Measuring Accuracy | ±7° |
Note: a) Compass Measurements valid for device inclination between -20° and +20° to horizontal. Measurements taken outside that range appear as “—“. b) Result is referred to magnetic north. |
|
Protection | |
Ingress Protection | IEC 60529: IP40 |
General Specifications | |
Battery Life (typical) | 50 hours (≤9000 readings) |
Weight | 231 g (8.14 oz) |