Electronic, 2 Conductor 18AWG (16×30) Tinned Copper, PE Insulation, Overall Beldfoil® Shield, PVC Outer Jacket, CM
| Suitable Applications | low voltage analog signals (4-20ma, 0-10v, …); low voltage digital control (24v, …); line level audio; computer communication; panel wiring |
|---|
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Pair(s) | 1 | 18 AWG | 16×30 | TC – Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Pair(s) | PE – Polyethylene | 0.018 in (0.46 mm) | 0.082 in (2.1 mm) | Black, Clear |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7×28) TC |
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Max. Current |
|---|---|---|---|
| Pair(s) | 7.06 Ohm/1000ft | 27.2 pF/ft (89.2 pF/m) | 14 Amps per Conductor at 30ºC |
Temperature
| UL Temperature | Operating |
|---|---|
| 60°C | -20°C to +60°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 2.2 in (56 mm) | 2.2 in (56 mm) |
| Max. Pull Tension | 54.2 lbs (24.6 kg) |
|---|---|
| Bulk Cable Weight | 25 lbs/1000ft |